From 99d6fc6c193491ff19f041439261e2cc62d2839a Mon Sep 17 00:00:00 2001 From: Jeffy Chen Date: Thu, 7 Jul 2022 14:43:31 +0800 Subject: [PATCH 32/46] waylandsink: Wait 10s for toplevel window's configure event The original 100ms is racy when system is under heavy load. Signed-off-by: Jeffy Chen --- gst-libs/gst/wayland/gstwlwindow.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/gst-libs/gst/wayland/gstwlwindow.c b/gst-libs/gst/wayland/gstwlwindow.c index 33f4ba8..6f96d6f 100644 --- a/gst-libs/gst/wayland/gstwlwindow.c +++ b/gst-libs/gst/wayland/gstwlwindow.c @@ -426,7 +426,7 @@ gst_wl_window_new_toplevel (GstWlDisplay * display, const GstVideoInfo * info, wl_display_flush (gst_wl_display_get_display (display)); g_mutex_lock (&priv->configure_mutex); - timeout = g_get_monotonic_time () + 100 * G_TIME_SPAN_MILLISECOND; + timeout = g_get_monotonic_time () + 10 * G_TIME_SPAN_SECOND; while (!priv->configured) { if (!g_cond_wait_until (&priv->configure_cond, &priv->configure_mutex, timeout)) { -- 2.20.1